Electrical & Power · Backup Power Equipment
Emergency Generator
Portable generators are the leading cause of carbon monoxide deaths from consumer products in the US — not because generators are inherently dangerous, but because most of those deaths trace back to running one too close to the house. Proper placement and routine fuel maintenance make the difference between backup power and a real hazard.
All 9 zonesLifespan: 10–30 yrs depending on typeLeading cause of consumer-product CO deathsElectrical & Power
Portable generator cost
$500–$2,500
unit only
Standby generator cost
$6,000–$11,000+
installed, 13–22kW home system
CO deaths from portable generators
~92/yr
the leading cause of non-fire CO deaths (CPSC)
DIY-able tasks
~55–60%
of routine maintenance
Something not working right?
Answer a few quick questions and get a personalized diagnosis from the HomeShape Repair Coach.
Select your type
Portable generator — a wheeled, gasoline- or propane-fueled backup generator, typically 3,000–10,000 running watts, used to power select circuits during short outages. Lifespan is roughly 1,000–2,000 hours of use, 10–15 years with good maintenance — but most failures come from fuel and storage neglect, not the engine wearing out. This is the type responsible for the vast majority of CO deaths, because it’s the type most often run too close to the house. Always operate at least 20 feet from the home, exhaust directed away from windows and doors, never in a garage, basement, or shed.
Maintenance tasks
| Task | Cadence | Skill | Time | Consequence if skipped |
|---|---|---|---|---|
Change the engine oil Small 4-stroke engine, similar to a lawnmower | Every 50–100 hrs of run time, or annually if idle | 2 · Confident | 20 min | Engine seizes or wears out early — the most common cause of shortened engine life |
Replace or clean the air filter Foam or paper element keeps dust and debris out of the carburetor | Every 50–100 hrs, or annually | 1 · Beginner | 10 min | Reduced power, poor fuel economy, eventual carburetor fouling |
Inspect and gap or replace the spark plug Fouled or worn plugs cause hard starting | Annually | 2 · Confident | 15 min | Hard starting, misfires, or won't start at all when needed |
Stabilize or drain fuel before storage Gasoline degrades and gums the carburetor jets in as little as 30 days | Before any storage period over 30 days | 1 · Beginner | 15 min | The #1 real-world cause of "won't start" in an actual outage |
Run the unit under load monthly Engines that sit unused develop fuel and seal issues | Monthly | 1 · Beginner | 30 min | Silent failures go undetected until the outage moment |
Inspect the CO shutoff sensor Built-in sensor that auto-shuts the unit down in high CO (on UL 2201 models) | Before storage season, annually | 2 · Confident | 10 min | Loses the single most important life-safety feature the unit has |
Troubleshooting
Symptom
Likely cause
Action
Who
Won't start after sitting unused
Stale or gummed fuel in the carburetor
Drain old fuel, clean carburetor jets or replace the rebuild kit, use fresh fuel with stabilizer going forward
DIY ok
Runs but no power output at outlets
A tripped breaker on the unit, or a failed capacitor/AVR
Reset the unit's own breaker; if that doesn't fix it, the capacitor or AVR needs replacement
Call pro
Engine surges or runs rough
A dirty carburetor, bad fuel, or a clogged air filter
Clean or replace the air filter first; if unresolved, clean the carburetor
DIY ok
Generator running in a garage or near an open window, occupants feel dizzy or nauseous
Carbon monoxide accumulation
Evacuate the house immediately, get to fresh air, call 911 — do not go back in to shut it off
Evacuate
Generator placed under a porch or less than 20 ft from the house "to keep it dry"
CO exhaust migrating into the living space even though it's technically outdoors
Move it to open air at least 20 ft away, exhaust directed away from the house, before restarting
Evacuate
Recommended tools & materials
Inverter generator — a smaller, more fuel-efficient portable generator (1,000–4,000 watts) that produces “clean” power safe for laptops, phones, and medical equipment, at roughly 50–60 dB versus 80+ for conventional units. Favored for quiet residential backup and camping. Same small gas engine as a conventional portable, so fuel neglect is still the dominant failure risk, not the electronics — and “quiet” does not mean safe to run indoors.
Maintenance tasks
| Task | Cadence | Skill | Time | Consequence if skipped |
|---|---|---|---|---|
Change the engine oil Inverter engines use less oil than conventional units — easy to overfill | Every 50–100 hrs or annually | 2 · Confident | 15 min | Overfilling fouls plugs; underfilling seizes the engine |
Clean or replace the foam air filter Most inverter models use a washable foam element | Every 25–50 hrs or seasonally | 1 · Beginner | 10 min | Reduced efficiency, harder starting, can trip auto-idle sensor errors |
Stabilize fuel or run the tank dry before storage A small fuel tank makes stale fuel issues develop faster | Before storage over 30 days | 1 · Beginner | 15 min | A gummed carburetor is the #1 inverter generator repair call |
Check and clean the spark arrestor screen Required for wooded/camping use, also affects performance | Every 100 hrs or annually | 2 · Confident | 15 min | Reduced power, and can be a legal requirement for camping or wilderness use |
Verify the Eco-mode / auto-idle sensor Feature that throttles engine speed to match load, key to fuel savings | Annually | 1 · Beginner | 5 min | Loses the fuel-efficiency advantage and can cause voltage instability under load |
Test with sensitive electronics periodically Confirm clean sine-wave output is holding up as the unit ages | Annually | 1 · Beginner | 5 min | Aging inverter components can start producing dirty power without obvious symptoms |
Troubleshooting
Symptom
Likely cause
Action
Who
Won't start, or starts and immediately dies
Stale fuel in the small carburetor or fuel bowl
Drain and replace the fuel, clean the carburetor if needed
DIY ok
Connected electronics behave erratically or won't charge
Eco-mode instability under fluctuating load, or aging inverter components
Disable Eco-mode for sensitive-load use; if it persists, the inverter board needs service
Call pro
Unit runs but output wattage seems low
Altitude derating, a dirty air filter, or a worn spark plug
Check altitude adjustment settings, clean or replace the air filter and spark plug
DIY ok
Used indoors, in a tent, or in an attached garage "because it's quiet"
Even quiet inverter models are still combustion engines producing lethal CO
Evacuate to fresh air immediately and call 911 if anyone shows CO symptoms — "quiet" does not mean safe indoors
Evacuate
Recommended tools & materials
Standby generator — a permanently installed unit, usually natural gas or propane fueled (10–48kW), wired through an automatic transfer switch that senses a utility outage and starts itself within seconds. Typical lifespan 20–30 years, but virtually all manufacturers require annual professional service to preserve the warranty — most owners aren’t permitted or equipped to do that service themselves.
Maintenance tasks
| Task | Cadence | Skill | Time | Consequence if skipped |
|---|---|---|---|---|
Confirm the weekly self-test cycle ran The unit auto-runs itself briefly every week to stay ready | Weekly (automatic; homeowner just confirms) | 1 · Beginner | 2 min | A failed self-test that goes unnoticed means finding out it's dead during the actual outage |
Visually inspect the unit and enclosure Debris, pests, and vegetation are common real-world failure triggers | Monthly | 1 · Beginner | 10 min | Blocked air intake causes overheating shutdown; rodents chew wiring |
Check the start battery and terminals Battery failure is the #1 cited cause of standby no-starts | Monthly visual, annual load test | 2 · Confident | 5–15 min | A dead start battery means the generator sits silent during the exact moment you need it |
Get oil, oil filter, and air filter service Small engine service, same principle as a car | Annually, or every 100–200 hrs | 3 · Advanced | 1–2 hrs (pro) | Voids the manufacturer warranty and shortens the engine's 20+ year lifespan |
Get a full load-bank or operational test Confirms the unit can actually carry real house load, not just start | Annually | 3 · Advanced | 1–2 hrs (pro) | The unit may start fine but stall or trip under real household load during an outage |
Get the automatic transfer switch (ATS) inspected The switch that isolates the home from utility power during transfer | Annually | 3 · Advanced | 30–60 min (pro) | A failed transfer switch means power never reaches the house — or can backfeed the utility line |
Troubleshooting
Symptom
Likely cause
Action
Who
Weekly self-test didn't run or has no log
A dead start battery or a controller fault
Check and replace the start battery first; if that doesn't resolve it, call for service
Call pro
Generator starts during an outage but the house has no power
A failed or misconfigured automatic transfer switch
Don't attempt to open or rewire the ATS yourself — it involves utility-level voltage and backfeed risk
Call pro
Generator shuts down shortly after starting under load
Low fuel pressure, a clogged fuel filter, or an overload
Check the propane tank level and valve is open; if natural gas or unresolved, call for fuel-system service
Call pro
Generator won't crank at all, clicking sound
A dead or failing 12V start battery
Test and replace the start battery, same as a car battery
DIY ok
Strong gas odor near the unit or gas line
A fuel line leak
Do not start or approach the unit — leave the area, don't operate any switches, call the gas utility from a safe distance
Evacuate
Recommended tools & materials
Battery backup power station — a rechargeable, almost always lithium iron phosphate (LiFePO4), unit that stores power from a wall outlet or solar panels and outputs it silently indoors, with zero combustion and zero CO risk. Capacity ranges roughly 500Wh–5,000+Wh, good for electronics and select appliances rather than whole-home loads. LiFePO4 cells are rated for 3,000–5,000 charge cycles and typically last 10–15 years — the main “maintenance” is charge-level and temperature management, not mechanical service.
Maintenance tasks
| Task | Cadence | Skill | Time | Consequence if skipped |
|---|---|---|---|---|
Maintain proper storage charge level Storing at 100% or 0% causes irreversible capacity loss | Before any storage period | 1 · Beginner | 5 min | Permanent capacity loss versus a unit stored at the recommended ~50% |
Top off the charge periodically during storage Even at 50%, batteries self-discharge slowly over months | Every 3 months | 1 · Beginner | 10 min | Deep discharge during storage can permanently damage cells or trip battery protection |
Keep the unit within a safe temperature range LiFePO4 degrades faster outside roughly 32–95°F | Ongoing | 1 · Beginner | — | Prolonged heat accelerates degradation; charging near freezing can permanently damage cells |
Clean terminals and vents Dust and corrosion on ports and vents affect charging and cooling | Annually | 1 · Beginner | 10 min | Poor cooling airflow shortens battery life; dirty contacts cause charging faults |
Update firmware / BMS software The Battery Management System firmware controls charge balancing and safety cutoffs | As released, check annually | 1 · Beginner | 10–15 min | Missing updates to the system that manages charge balancing and thermal cutoffs |
Exercise the unit under load Confirms the inverter and battery still deliver rated output | Every few months | 1 · Beginner | 15 min | Latent inverter or cell faults go undetected until the outage moment |
Troubleshooting
Symptom
Likely cause
Action
Who
Battery won't hold a charge like it used to
Normal capacity fade near end of rated cycle life, or repeated storage at 100%/0%
Check the age against rated cycle life; if premature, contact manufacturer warranty support
Call pro
Unit won't charge from solar panels
A loose or corroded connector, damaged panel cable, or insufficient sun angle
Inspect and reseat connectors, test panel output with a multimeter if available
DIY ok
Unit feels warm or hot and shuts itself down
Built-in thermal protection triggered by high ambient temperature or high load
Move it to a cooler, ventilated location and let it cool — this is the safety system working correctly
DIY ok
Unit is swollen, leaking, or smells strongly chemical
Battery cell damage or thermal runaway risk
Stop using it immediately, move it away from flammable materials if safe to do so, don't charge or discharge it further, contact the manufacturer
Evacuate
Recommended tools & materials
Relevant In Your Zone
The Deep Freezer
Heavy snow and ice are a common cause of winter outages.
The Windy High Plains
High wind exposure is a top cause of downed power lines.
The Alaska / Alpine Extreme
Extreme winters make backup power worth having on hand.
Related Guides
Want these tasks on your maintenance calendar?
HomeShape builds a free 12-month calendar specific to your climate zone.
Enter your ZIP and tasks like these are scheduled automatically — timed correctly for where you live.
Get My Free Maintenance CalendarEnter your ZIP and tasks like these are scheduled automatically — timed correctly for where you live.
Free · No account required · Takes 30 seconds